Agilent 1260 Chemstation Software Manual
Agilent 1260 Chemstation Software Manual Free Download Pdf This particular Agilent 1260 Chemstation Software Manual PDF start with Introduction, Brief Session till the Index/Glossary page, look at the table of content for additional information, when presented. Manual Part Number M8301-90019 Rev. B Edition 06/2018 Printed in Germany. In the following, the term ChemStation always refers to Agilent OpenLab CDS ChemStation Edition. In this manual we describe the efficient use of the data acquisition, analysis. About the ChemStation Software 12 ChemStation Data Structure 42 2 Working with. Agilent 1260 Infinity Variable Wavelength Detector User Manual. Defense purchases, DFARS 252.227-7015 (Technical Data - Commercial Items) and DFARS 227.7202-3 (Rights in Commercial Computer Software or Computer Software Documentation).
1 Standard Operating Procedure Remcho Research Group P a g e 1 Agilent 1100 HPLC ChemStation 1) Turn on all the modules for HPLC system (CapPump G1376A, DAD G1315B) and allow for system to initialize. 2) Turn on the computer, open the ChemStation software by clicking Start -Programs - Agilent Chemstation - Instrument 1 online 3) Choose configuration that will be used (Capillary pump G1376A and DAD G1315B) and click OK. 4) Under the Instrument menu, choose System On to turn on pump and DAD or use the shoutcut button on the instrument control page. 5) It is recommended to flush the reservoir lines before your column is connected to the HPLC system. Click at the pump interface - Purge - More. 7 Standard Operating Procedure Remcho Research Group P a g e 7 - The instrument data curve (i.e.
Agilent Chemstation Software Download
Mobile phase compositions, Flow rate, Temterature, Pressure or UV lamp voltage) can be overlaid to the chromatogram. After Method is set, save the method. Under File menu - Save as - Method - Put the method name 9) Run a single sample 9.1) Put the sample information; Under RunControl - Sample Info Insert sample information i.e. Operator name, Subdirectory, File name (prefix/counter can be used.), Sample name, and Comments (The running condition can be entered in this field such as, sample information, mobile phase composition, Flow rate, Injection volume ). 9 Standard Operating Procedure Remcho Research Group P a g e 9 10) Data Analysis 10.1 The chromatogram is processed in the Data Analysis Tab (second tab on the left panel). Load the chromatogram by click File - Load Signal - Choose the desired file name Integration tool bar The peaks on the chromatogram can be manually integrated or deleted by using integration tool bar The chromatogram can be printed out Under File menu - Print Preview - Report and Click Print 11) Once the running is finished, Flushing the analytical column with high percent of methanol or acetonitrile and keep it in storage solution (see the column manual).
Agilent 1260 Chemstation Software Manual
12) Turn off the pump and the lamp by click the DAD - Control and click off for both UV and Vis lamps. You can close out the software, and turn off the instrument (Micropump and DAD).